OKi Knowledge Base
25 cases in knowledge base
No cases match your search.
Propulsion · EVO-002-Knowledge-Case-Torqeedo-E30-defective-communication-motor
Torqeedo E30 — Defective Communication with Motor
E30 is a communication fault between the Torqeedo display unit and the motor controller. It is not n…
E30 error code on Torqeedo displayDisplay shows — Defective communication with motorDisplay shows — Check main switch · Check battery connectionMotor not responding — zero RPM · zero watts
General · 006-Knowledge-SOL-mppt-zero-watts-mc4
Solar Showing 0W — MPPT Relay Open, MC4 Connectors Unplugged
Solar panels had been replaced after the originals were damaged. During reinstallation the MC4 conne…
Solar showing 0W in Victron systemMPPT BULK LED flashing but no charging currentVictronConnect shows 0V panel voltageCerbo GX MPPT page shows relay open
General · 002-Knowledge-Case-AC-parallel-multplus-fault
Parallel MultiPlus Fault — One Unit Offline in Dual Inverter System
In a dual Victron MultiPlus parallel installation, one unit dropped off the VE.Bus network. Root cau…
Only one MultiPlus visible in Victron system or VictronConnectVE.Bus error or warning on Cerbo GX displayMG Master contactor not engaging — no audible click when system powers upCharging unstable or not reaching float
General · 001-Knowledge-Case-AC-shore-power-overheating-multiplus-offline
Shore Power Charger Failure — Overheating, Burned Shore Connector, MultiPlus Offline, MG Safety Contactor Open
A cascade of related faults on a dual-phase Victron MultiPlus + eMotion MG Master hybrid catamaran: …
Shore connector (CEE pimenteiro) overheating or burnedMarina circuit breaker tripping within 1–2 hours of chargingMultiPlus charge current not following Victron limit settingOne MultiPlus not visible in Cerbo GX device list
General · HW-001
No Hot Water — Circuit Breaker Off or Tripped (Single or Multi-Zone)
Domestic hot water unavailable at some or all taps. The 220V AC water heater element is not receivin…
no hot water at shower or galley tapcold water only from hot taphot water present at some taps but not othersforward cabins cold, aft cabins hot — or vice versa
General · HW-002
No Hot Water — Forward Zone Cold, Aft Zone Warm (Multi-Zone System)
Partial hot water loss on a vessel with two or more independent water heater units. The aft zone hea…
hot water in aft cabins and cockpitno hot water in forward cabinsshore power or inverter confirmed healthymain AC distribution normal
General · 003-Knowledge-ANC-overnight-anchor-energy
Overnight Anchor — Energy Management
At anchor overnight, shore power is disconnected and solar stops at sunset. On ALUNA (72kWh @ 24V), …
Shore power disconnected at anchorBattery discharging with no charging source activeSolar at zero from sunset to sunriseAC units running overnight on battery only
General · 007-Knowledge-SOL-mppt-no-charge-fuse
Solar MPPT No Charge — Panel Voltage Present, Zero Output
MPPT controller was receiving panel voltage at its input but producing zero charge current. Root cau…
Solar power showing 0W in Victron systemMPPT is online and visible on Cerbo GXPanel voltage present when measured directly at panelsBattery not charging from solar despite adequate sunlight
General · 004-Knowledge-BAT-service-battery-collapse
Service Battery Collapse — Remote Recovery Coordination
Service battery dropped below 12V due to insufficient winter maintenance and energy management negle…
Service battery voltage below 12VCharging state uncertain or inconsistentRisk of total battery collapse and loss of all onboard systemsOperator unsure of safe disconnection sequence
General · EP-E01
ePropulsion E01 — Battery Voltage Out of Range
Battery voltage is outside the permitted operating range — either too high or too low for the motor …
E01 error code displayedmotor shutdown or refusal to startbattery voltage reading outside normal band
General · EP-E02
ePropulsion E02 — Motor Overcurrent / Propeller Blocked
Motor drawing excessive current. Two causes: propeller physically blocked by fouling, rope or debris…
E02 error code displayedmotor sudden shutdown under loadunusual resistance or drag on propellermotor overloaded
General · EP-E06
ePropulsion E06 — Low Battery Voltage Under Load
Battery voltage dropped too low during motor operation. Under load, internal resistance causes volta…
E06 error code displayedmotor shutdown under loadvoltage sag visible on battery monitorfault occurs at throttle above minimum
General · EP-E10
ePropulsion E10 — Motor Stall / Propeller Blocked
Motor stalled — propeller physically obstructed and unable to rotate. Common causes: rope, fishing l…
E10 error code displayedmotor stopped suddenlysudden loss of thrustunusual noise before stall
General · EP-E11
ePropulsion E11 — Motor Overheating
Motor temperature exceeded safe operating limit. Caused by sustained high-load operation, blocked co…
E11 error code displayedmotor shutdown after sustained high-power operationwarm or hot motor casingreduced performance before shutdown
General · EP-E12
ePropulsion E12 — Circuit Board Overheating
Controller circuit board temperature exceeded safe limit. Usually caused by high ambient temperature…
E12 error code displayedmotor shutdown after sustained operationcontroller area hot to touch
General · EP-E15
ePropulsion E15 — Circuit Board Temperature Sensor Failure
Internal fault: temperature sensor on circuit board has failed or is reading incorrectly.
E15 error code displayedmotor may shut down or refuse to start
General · EP-E16
ePropulsion E16 — Current Sensor Calibration Fault
Current sensor calibration abnormality. Internal fault requiring dealer attention.
E16 error code displayed
General · EP-E21
ePropulsion E21 — Driver / Motor Communication Fault
Communication failure between controller and motor driver. May be a version mismatch between Evo Sid…
E21 error code displayedmotor unresponsive to throttlecommunication lost between controller and motor
General · EP-E22
ePropulsion E22 — MCU Communication Abnormality
Microcontroller unit communication fault. Internal communication error within the motor management s…
E22 error code displayedmotor shutdown or erratic behaviour
General · EP-E30
ePropulsion E30 — Throttle Position Sensor Failure / Recalibration Required
Throttle position sensor is out of calibration or has failed. Motor cannot accurately read throttle …
E30 error code displayedthrottle not responding correctlyerratic speed controlmotor speed not matching throttle position
General · EP-E40
ePropulsion E40 — System Running Failure
General system fault during operation. The motor management system detected an unrecoverable error d…
E40 error code displayedmotor shutdown during operation
General · EP-E56
ePropulsion E56 — Battery Communication Error
Communication fault between motor and E-series battery. Usually a cable connection issue between the…
E56 error code displayedmotor unable to read battery statemotor shutdown or refusal to start
General · EP-E57
ePropulsion E57 — E-Series Battery Overcurrent
Battery discharge current exceeded safe limit. In parallel battery configurations, voltage imbalance…
E57 error code displayedmotor shutdown under high loadparallel battery voltage imbalancepoor cable contact
General · 005-Knowledge-EVO-torqeedo-no-power
Torqeedo Motor Dead — Victron Screen Drops When Key Turned
The 12V ignition key circuit was pulling down the Victron display power when activated, indicating a…
Torqeedo display does not light upVictron MPPT or GX display goes dark when ignition key is turnedMotor will not respondBattery has sufficient charge and solar is functioning normally
General · 001-Knowledge-Case-AC-shore-power-multiplus-replacement
Shore Power Charger Failure — Overheating, Intermittent VE.Bus, 3-Way Switch Fault, MultiPlus End of Life
Progressive wear on the Victron MultiPlus 3-way switch (I · II · O). Internal contact degrades over …
Shore connector (CEE) overheating — inlet temperature above 65°CMarina circuit breaker tripping within 1–2 hours of chargingL2 phase drawing above set current limit — 33A against 24A limitMultiplus offline — not visible in Cerbo GX device list